簡單介紹
CH8711A程控直流電子負載|常州貝奇直流電子負載.負載消耗較大電流時,將在被測電源到負載的連接線上產生電壓降,從而影響電壓測量精度。在CV,CR,CP模式下,電壓采樣精度將影響到電子負載的工作精度,采用遠端測試功能可完全消除電壓降對測試的影響
產品描述
.jpg)
CH8711A程控直流電子負載|常州貝奇直流電子負載
.jpg)
CH8711A程控直流電子負載|常州貝奇直流電子負載
|
型號
|
CH8711
|
CH8712
|
CH8711A
|
CH8712A
|
CH8711B
|
CH8712B
|
|
|
額定值
|
輸入電壓
|
0~120V
|
0~120V
|
0~360V
|
0~360V
|
0~60V
|
0~60V
|
|
輸入電流
|
1mA~30A
|
1mA~30A
|
1mA~30A
|
1mA~30A
|
1mA~60A
|
1mA~60A
|
|
|
輸入功率
|
150W
|
300W
|
150W
|
300W
|
150W
|
300W
|
|
|
|
量程
|
精度
|
分辨率
|
精度
|
分辨率
|
精度
|
分辨率
|
|
負載精度
|
0-18V
|
±(0.1%+0.03%FS)
|
1mV
|
±(0.1%+0.03%FS)
|
1mV
|
±(0.1%+0.03%FS)
|
1mV
|
|
0-120V/360V
|
±(0.1%+0.03%FS)
|
10 mV
|
±(0.1%+0.03%FS)
|
10 mV
|
±(0.1%+0.03%FS)
|
10 mV
|
|
|
0-3A
|
±(0.1%+0.1%FS)
|
1 mA
|
±(0.1%+0.1%FS)
|
1 mA
|
±(0.1%+0.2%FS)
|
1mA
|
|
|
0-15A/30A
|
±(0.2%+0.15%FS)
|
1 0mA
|
±(0.2%+0.3%FS)
|
10 mA
|
±(0.2%+0.5%FS)
|
10 mA
|
|
|
定電壓模式
|
1.5V-18V
|
±(0.1%+0.03%FS)
|
1mV
|
±(0.1%+0.03%FS)
|
1mV
|
±(0.1%+0.03%FS)
|
1mV
|
|
1.5V-120V/360V
|
±(0.1%+0.03%FS)
|
10 mV
|
±(0.1%+0.03%FS)
|
10 mV
|
±(0.1%+0.03%FS)
|
10 mV
|
|
|
定電流模式
|
0-3A
|
±(0.1%+0.1%FS)
|
1 mA
|
±(0.1%+0.1%FS)
|
1 mA
|
±(0.1%+0.2%FS)
|
1mA
|
|
0-15A/30A
|
±(0.2%+0.15%FS)
|
10 mA
|
±(0.2%+0.3%FS)
|
10 mA
|
±(0.2%+0.5%FS)
|
10mA
|
|
|
定電阻模式
|
0.1Ω-10Ω
|
±(1%+0.3%FS)
|
0.001Ω
|
±(1%+0.3%FS)
|
0.001Ω
|
±(1%+0.3%FS)
|
0.001Ω
|
|
10Ω-99Ω
|
±(1%+0.3%FS)
|
0.01Ω
|
±(1%+0.3%FS)
|
0.01Ω
|
±(1%+0.3%FS)
|
0.01Ω
|
|
|
100Ω-999Ω
|
±(1%+0.3%FS)
|
0.1Ω
|
±(1%+0.3%FS)
|
0.1Ω
|
±(1%+0.3%FS)
|
0.1Ω
|
|
|
1KΩ-4KΩ
|
±(1%+0.8%FS)
|
1Ω
|
±(1%+0.8%FS)
|
1Ω
|
±(1%+0.8%FS)
|
1Ω
|
|
|
定功率模式
|
0-10W
|
±(1%+0.1%FS)
|
1 mW
|
±(1%+0.1%FS)
|
1 mW
|
±(1%+0.1%FS)
|
1 mW
|
|
10-100W
|
±(1%+0.1%FS)
|
1 0mW
|
±(1%+0.1%FS)
|
10 mW
|
±(1%+0.1%FS)
|
1 0mW
|
|
|
100-300W
|
±(1%+0.1%FS)
|
0.1W
|
±(1%+0.1%FS)
|
0.1 W
|
±(1%+0.1%FS)
|
0.1 W
|
|
|
電流測量值
|
0-3A
|
±(0.1%+0.1%FS)
|
1 mA
|
±(0.1%+0.1%FS)
|
1 mA
|
±(0.1%+0.2%FS)
|
1mA
|
|
0-15A/30A
|
±(0.2%+0.15%FS)
|
10 mA
|
±(0.2%+0.3%FS)
|
10 mA
|
±(0.2%+0.5%FS)
|
10 mA
|
|
|
電壓測量值
|
1.5V-18V
|
±(0.1%+0.03%FS)
|
1mV
|
±(0.1%+0.03%FS)
|
1mV
|
±(0.1%+0.03%FS)
|
1mV
|
|
1.5V-120V/360V
|
±(0.1%+0.03%FS)
|
10 mV
|
±(0.1%+0.03%FS)
|
10 mV
|
±(0.1%+0.03%FS)
|
10 mV
|
|
|
功率測量值
|
0-10W
|
±(1%+0.1%FS)
|
1 mW
|
±(1%+0.1%FS)
|
1 mW
|
±(1%+0.1%FS
|
1 mW
|
|
10-100W
|
±(1%+0.1%FS)
|
1 0mW
|
±(1%+0.1%FS)
|
10 mW
|
±(1%+0.1%FS
|
10 mW
|
|
|
100-300W
|
±(1%+0.1%FS)
|
0.1W
|
±(1%+0.1%FS)
|
0 .1W
|
±(1%+0.1%FS
|
0.1 W
|
|
|
電池測試功能
|
Input= 0.8-120V Max measurement capacity= 999A/H
Resolution=10 mA Timer range=1~60000sec
|
||||||
|
動態測試模式
|
Range of Frequency 0.1Hz-1KHz
Frequency errorrate <0.5%
|
||||||
產品留言
- 溫馨提示:為規避購買風險,建議您在購買前務必確認供應商資質與產品質量。
- 免責申明:以上內容為注冊會員自行發布,若信息的真實性、合法性存在爭議,平臺將會監督協助處理,歡迎舉報